Infection control and staged access in operating facilities.

Clinics, day surgeries, consulting suites, allied health and hospital departments across South Australia, Victoria and New South Wales. Built beside patients who are already there.

Group
Workplace and public
  • A completed medical consulting suite with a clean treatment room, illustrative of the building type
  • A completed suburban medical centre with an entry canopy, illustrative of the building type
  • A completed medical consulting room with a clinical basin, illustrative of the building type
Project capacity under a single contract
$20m
States we build in: South Australia, Victoria and New South Wales
3
Years of the director’s delivery experience
15+
Every instruction priced and approved in writing
100%

The constraint

In a health facility, dust is a clinical risk.

Construction dust in an operating healthcare environment is not an amenity issue. It carries organisms, and the people on the other side of the hoarding are the least able to tolerate them.

This changes the way the work is planned rather than the way it is built. The construction zone is sealed and held below the pressure of the spaces around it, so that air moves in rather than out. Entry and exit happen through an anteroom. Air is filtered and exhausted away from clinical areas. And the pressure differential is monitored continuously, because a control that is set up once and assumed is not a control.

The health service defines the risk level for the work and the precautions that follow. Our job is to build inside that framework and to give the infection prevention team something they can verify rather than something they have to trust.

  1. Patients and staff

    Clinical area, in use

    higher pressure

  2. Anteroom

    entry, exit, tack mat, PPE

  3. Construction zone

    held at negative pressure; air filtered, then exhausted away

  4. Exhaust

    to outside

Air always moves toward the works and never out of them. The direction of that arrow is the whole control.

It is monitored continuously, not set up once and assumed.

The containment arrangement for construction inside an operating health facility. Every element exists to keep the arrow pointing one way.

The rest of it

What else a health project carries.

Medical gases
Installation, modification and certification of medical gas systems are specialist, licensed work with their own verification regime. They are also frequently on the critical path because the certification cannot be rushed.
Imaging and shielding
Radiation shielding is designed by a specialist and verified after installation. It affects the structure, the door hardware, the penetrations and the room sequence, and it cannot be adjusted once the room is finished.
Essential and resilient services
Emergency power, uninterruptible supply, nurse call and medical monitoring cannot be interrupted casually. Every isolation is a clinical decision as well as a construction one.
Facility guidelines
Health projects are commonly designed to the health facility guidelines used in Australia and New Zealand, alongside the health service’s own standards. Building to a room data sheet is a different discipline from building to a drawing.
Finishes and cleanability
Coved junctions, sealed joints, impact resistance and surfaces that survive hospital-grade cleaning chemistry. Finish selection in health is a technical decision.
Commissioning and clinical handover
Rooms are handed over to a clinical team who need to be trained on what is in them, with the certificates in hand. We plan the handover as a stage rather than a day.

Certification

Who has to approve a health facility, and in which state.

A health or laboratory facility answers to more than the building code. Knowing which body signs off what, and when, is most of the programme.

Every state licenses private health facilities separately, and each health service also carries its own capital works and design requirements above the licence. On top of that sit the national design guidelines that most public and many private projects are designed to, and, for a testing or research laboratory, an entirely separate accreditation and containment regime.

None of these is a builder’s approval to give. What a builder can do is know the sequence, get the evidence collected while the work is happening, and stop a project reaching completion with a room that cannot be licensed.

What it governsWho holds itWhat it means for construction
Private health facility licensingThe state health department in each of South Australia, Victoria and New South Wales, under that state’s own health legislation.Room sizes, adjacencies, sanitary and clinical provision are assessed against the licence category. A change of category mid-project changes the room, not the paperwork.
Health service capital works standardsThe health service or operator itself.Frequently stricter than the code on finishes, hardware, services and infection control. Ask for the standard at concept, because it is rarely volunteered.
Australasian Health Facility GuidelinesThe design reference used across Australia and New Zealand.Projects are designed to room data sheets rather than to drawings. Building to a room data sheet is a different discipline and a different set of checks.
Laboratory accreditationThe national accreditation body for testing and calibration laboratories.The facility has to support the accredited method: environmental control, separation, and a documented performance record from day one.
Physical containmentThe Australian and New Zealand standard for safety in laboratories, with a separate regulator where genetically modified organisms are handled.Containment level drives pressure regime, finishes, penetrations, decontamination and the certification testing at the end.
Radiation and imagingThe state radiation regulator.Shielding is designed by a specialist, verified after installation, and cannot be adjusted once the room is finished.

Named by function rather than by instrument title, because titles and administering bodies change. Your project team should confirm the current instrument for your state and category.

The people on the other side of the hoarding are the least able to tolerate what is on our side of it.

A completed medical consulting suite with a clean treatment room, illustrative of the building type

Where we add value

What we are genuinely good at here.

  1. StagingSequencing works so that a department keeps functioning. Decant, temporary arrangements, and handing back space in a state that can be used.
  2. CoordinationHealth projects carry more specialist contractors and certifiers than almost any other building type. Holding that interface is most of the work.
  3. EvidenceCertificates, verification records, commissioning data and as-builts collected as the work happens, so the facility inherits a documented asset.
  4. CommunicationClinical staff need to know what is happening tomorrow, not next month. Short, frequent, accurate.

Projects

Prior firm: the director’s contribution at a previous firm, not JCGAU-delivered work.

Questions

Can you work in an operating clinical area?

Yes, inside the risk framework the health service sets. We build the containment, monitor it and give the infection prevention team the records to verify it.

Can you stage the work so we keep seeing patients?

Usually. Decant and staged handback are normal in health work, and they are designed into the programme from the start rather than added later.

Do you work with our specialist consultants?

Yes. Medical gas, shielding, and clinical planning specialists are typically appointed by the health service, and we coordinate to them.

What size health projects do you take?

Up to $20 million under a single contract. Consulting suites, day surgeries, clinics and departmental refurbishments rather than whole hospitals.

Other sectors

Tell us what has to keep running.

The clinical constraint shapes a health programme more than the design does. It is the right place to start.